The University of Tokyo
Medical School Hospital
Department of Radiology
Update date:2022/09/25
Other Staff
FUJII KEITA

Papers

  1. Accelerated Two-Point Dixon MR Angiography Improves Diagnostic Performance for Cervical Artery Diseases.2022/09Amemiya Shiori,Takei Naoyuki,Ueyama Tsuyoshi,Fujii Keita,Takao Hidemasa,Yasaka Koichiro,Watanabe Yusuke,Kamiya Kouhei,Abe OsamuJournal of magnetic resonance imaging : JMRI56/ 3, 929-94110.1002/jmri.281221522-2586Nonenhanced MR angiography (MRA) studies are often used to manage acute and chronic large cervical artery disease, but lengthy scan times limit their clinical usefulness.To develop an accelerated cervical MRA and test its diagnostic performance.Prospective.Patients with cervical artery disease (n = 32, 17 males).3.0 T; accelerated two-point Dixon three-dimensional Cartesian spoiled gradient-echo (FLEXA) and conventional time-of-flight MRA (cMRA) sequences.All patients underwent FLEXA (1'28″) and cMRA (6'47″) acquisitions. Quantitative evaluation (artery-to-background signal ratio and a blur metric) and qualitative evaluation using diagnostic performance measured by the sensitivity, specificity, and positive/negative predictive values (PPV/NPV), and vessel and plaque visualization scores from three board-certified radiologists' (with 10, 11, and 12 years of experience) independent readings using maximum intensity projection (MIP) for luminal diseases and axial images for plaque. The reference standards were contrast-enhanced angiography and fat-saturated T1-weighted images, respectively.All measures were compared between FLEXA and cMRA using the paired t, Wilcoxon signed-rank, McNemar's, or chi-squared test, as appropriate. Interreader agreement was assessed using Cohen's κ. P < 0.05 was considered statistically significant.The artery-to-background signal ratio was significantly higher for FLEXA (FLEXA: 7.20 ± 1.63 [fat]; 4.26 ± 0.52 [muscle]; cMRA: 2.57 ± 0.49 [fat]), while image blurring was significantly less (FLEXA: 0.24 ± 0.016; cMRA: 0.30 ± 0.029). In luminal disease detection, sensitivity (FLEXA: 0.97/0.91/0.91; cMRA:0.71/0.69/0.63), specificity (FLEXA: 0.98/0.93/0.98; cMRA:0.93/0.85/0.92), PPV (FLEXA: 0.92/0.86/0.86; cMRA: 0.64/0.5/0.58), and NPV (FLEXA: 0.99/0.98/0.98; cMRA: 0.92/0.91/0.9) were significantly higher for FLEXA. interreader agreement was substantial to almost perfect for FLEXA (κ = 0.82/0.86/0.78) and moderate to substantial for cMRA (κ = 0.67/0.56/0.57). MIP visualization scores were significantly higher for FLEXA, with substantial to almost perfect interreader agreement (FLEXA: κ = 0.83/0.86/0.82; cMRA: κ = 0.89/0.79/0.79). In plaque detection, sensitivity (FLEXA: 0.9/0.9/0.7; cMRA: 0.3/0.6/0.2) and specificity (FLEXA: 1/0.87/1; cMRA: 0.93/0.63/0.97) were significantly higher for FLEXA in two of three readers. The interreader plaque detection agreement was fair to substantial (FLEXA: κ = 0.63/0.69/0.48; cMRA: κ = 0.21/0.45/0.20). Side-by-side plaque and vessel wall visualization was superior for FLEXA in all readers, with moderate to substantial interreader agreement (plaque: κ = 0.73/0.73/0.77; vessel wall: κ = 0.57/0.40/0.39).FLEXA enhanced visualization of the cervical arterial system and improved diagnostic performance for luminal abnormalities and plaques in patients with cervical artery diseases.1 TECHNICAL EFFICACY STAGE: 2.
  2. O2-enhanced MRIにおけるRelative Enhancement Ratio Mapの動画作成に関する検討2014/11藤井 佳太, 渡辺 靖志, 花岡 昇平, 本吉 光一, 後藤 政実, 雨宮 史織, 井野 賢司, 赤羽 正章, 矢野 敬一, 大友 邦日本放射線技術学会雑誌70/ 11, 1290-129610.6009/jjrt.2014_JSRT_70.11.12900369-4305(公社)日本放射線技術学会O2-enhanced MRIにおけるRelative Enhancement Ratio Mapの動画作成について検討した。健常人6例を対象とした。作成したプログラムによって、数値ファントムおよび健常人の平均RER画像を作成し、数値ファントムの平均RER画像において、ベース濃度が異なるにもかかわらず、計算したカラーマップの画像が同一であることから、プログラムの計算が正しく行われていることを確認した。平均RERの異なる健常人において、造影効果および両者間での造影の程度に差が出ていることを視覚的に観察した。Cine RER mapによって、各々の経時的な造影効果を視覚的に観察した。各健常人での時間軸方向における左肺および左肺の信号強度、健常人間での室内空気における信号強度に有意差は認めなかった。
  3. MRI装置におけるSNRの経時変化(Longitudinal investigation of signal-to-noise ratio for magnetic resonance imaging scanners)2012/02後藤 政実, 藤井 佳太, 阿部 修, 青木 茂樹, 椛沢 宏之, 岩坪 威, 山下 典生, 松田 博史, 林 直人, 井野 賢司, 矢野 敬一, 大友 邦, Japanese Alzheimer's Disease Neuroimaging Initiative日本放射線技師会雑誌59/ 2, 179-1840287-9395(公社)日本診療放射線技師会MRI装置を用いた多施設参加型の研究において、装置の安定性を信号対雑音比(SNR)で評価するが、通常使用時におけるSNRの経時変化に関する詳細な検討が見当たらなかった。そこでSNRの経時変化を、複数種の装置において調査することを目的とした。この検討では、おおよそ1ヵ月の間に11回の測定を4機種それぞれで行った。SNR変化率(%)は(100×(1回のSNR-11回の平均SNR)/11回の平均SNR)と定義した。測定結果は下記(プロトコル名:最大値)のようになった。(GE3T protocol:9.85%)、(GE1.5T protocol:10.1%)、(SIEMENS protocol:9.63%)、(TOSHIBA protocol:5.87%)。1ヵ月の間における、4機種の装置でのSNR変化率は11%を超えなかったことから、11%を超えた場合に何らかの異常を疑うことができる。この研究は、多施設参加型研究における装置安定性を評価するために参考となるデータを提供する。(著者抄録)
  4. 心電図同期心筋血流SPECTによるcenterline法を用いた壁運動定量評価2008/07今江 禄一, 藤井 佳太, 高野 政明, 山崎 純一, 飯田 恭人, 美馬 和男, 篠原 広行日本放射線技術学会雑誌64/ 7, 814-82110.6009/jjrt.64.8140369-4305(公社)日本放射線技術学会心筋壁運動を定量評価するcenterline法を核医学分野に応用し、簡便で非侵襲的な三次元心筋壁運動を評価する手法の構築と、健常人による心筋局所壁運動の平均値マップと標準偏差(SD)マップの作成を検討した。この解析プログラムにはC言語が用いられ、以下の4点の手順で構成されている。1)短軸断層像の読み込み、2)centerline法による画像構築、3)解析・評価、4)データ保存。この解析プログラムを心電図同期心筋血流SPECT用動態ファントムとCTスキャンにより評価した。また、この手法を用いて健常人15名を対象とした標準心筋壁運動の平均値マップとSDマップを作成し、その有用性を検討した。その結果、この手法により被験者の壁運動を三次元的・定量的に評価することが可能であることが分かった。

Presentations

  1. O2-enhanced MRIにおけるDynamic Color Image作成に関する検討2013/09
  2. 320列CTを用いたprospective心電同期撮影における新再構成の画質評価2010/02
  3. Gated SPECTによる拡張型心筋症の壁運動異常およびEFについて2008/07
  4. Gated SPECTによる拡張型心筋症の壁運動異常およびEFについて2008/04